ISSN (0970-2083)

All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Influence of Repetitively Pulsed Negative Bias Parameters on Macroparticle Surface Density

A.I. Ryabchikov*, D.O. Sivin, A.I. Bumagina, A.E. Shevelev, I.A. Shulepov and P.S. Ananin

National Research Tomsk Polytechnic University, 634050, Tomsk, Russian Federation

*Corresponding Author:
A.I. Ryabchikov
National Research Tomsk Polytechnic University, 634050, Tomsk, Russian Federation
E-mail: shevelevae@tpu.ru

Received date: July 06, 2016; Accepted date: August 22, 2016

Visit for more related articles at Journal of Industrial Pollution Control

Abstract

The results of an experimental study of the influence of a substrate negative bias with various pulse widths and pulse repetition rates ranging from several Hz to 105 Hz on the macroparticle (MP) accumulation on substrate immersed in a DC titanium vacuum arc plasma are presented. It was found that the rate of MP deposition on the substrate surface depends significantly on the bias pulse parameters and the processing time. The influence of the multiple recharging of MPs in the plasma and the sheath on the reflection of these MPs in a sheath electric field is discussed.      

Keywords

Substrate negative bias, Macroparticle accumulation, Microdroplets, Vacuum arc plasma, Gaseous plasma

Introduction

The vacuum arc plasma is characterized by the high degree of the ionization of cathode material erosion products (Plyutto, et al., 1965; Lunev, et al., 1976; Kondrat’eva, et al., 1999). This benefit provides the wide practical application of vacuum arc plasma for different multifunctional ion implantation and coating deposition technologies (Sanders, 1989; Boxman, et al., 1995; Randhawa, 1988; Sharkeev, et al., 1995; Nikolaev, 2012). The main disadvantage of vacuum arc discharge, which considerably limits its applications, is the presence of significant amount of microdroplets often referred to as macroparticles (MPs). MPs have size 0.1 μm to 100 μm at velocities from 1 m/s to 800 m/s (Daalder, 1976; Rysanek, et al., 2008). The presence of MPs in the metal plasma leads to the creation of pores, the degradation of coating homogeneity and properties and a significant increase in their roughness.

A number of different MP filtering systems have been proposed and developed in order to obtain MP – free dense metal plasma. Nevertheless, an efficiency of vacuum arc plasma transportation throw the filters are low (Aksenov, et al., 1978; Anders, 1999; Ryabchikov, et al., 2005).

Many different approaches based on vacuum arc properties have been proposed and used to decrease MP number density in the coatings (Swift, 1996; Bizyukov, et al., 2006; Proskurovsky, et al., 2007).

The authors of several works observed the MPs density reducing effect on the TiN coating surface by 3-4 times with increasing DC negative bias potential up to φ=–1 kV on the substrate immersed in the vacuum arc plasma (Tau, et al., 1990; Keidar, et al., 1999).

Works (Zhanga, et al., 2012; Ryabchikov, et al., 2014; Stepanov, et al., 2016) described investigation of the possible enhancement of the MPs number decreasing effect by using high-frequency short-pulse negative bias with amplitude up to 3.2 kV.

This paper deals with the study of control possibility of titanium MP surface number density depending on processing time and repetitively pulsed bias parameters including bias pulse repetition rate and pulse width.

Materials and Methods

The experimental setup scheme is presented in Fig. 1. The vacuum arc and gaseous plasma sources were installed on the side flange of experimental setup. Titanium has been used as a cathode material. The variation of plasma density near the substrate surface was realized by means of the sample-plasma sources distance control.

icontrolpollution-experimental-installation-scheme

Fig. 1: The experimental installation scheme.

For carrying out the experimental investigations, two short-pulse negative bias generators were used. The first generator had fixed pulse width of 7 μs. The pulse repetition rate of this generator could be varied from 10 Hz to 2.5·104 Hz. The second generator had a fixes pulse frequency of 105 Hz with a possibility to control the pulse width from 1 μs to 9 μs. The negative bias pulse amplitude of the generators could be varied from 0.5 kV to 3.5 kV. Stainless steel and titanium have been used as substrates materials. The surface of samples has been polished (Ra=0.035 μm). The substrates surface was investigated using optical and electron microscopes.

Experimental data on MP number surface density change are presented in the figures in absolute units and in the form of MP relative number surface density k=N/N0=n/n0, where N=n × S is the quantity of MPs located on the chosen area of a substrate (S) at negative biasing; n is the number surface density of MPs at negative biasing; N0=n0 × S is the quantity of MPs on the chosen area of a substrate at anode potential (φb=0 V) at the chosen vacuum arc plasma deposition time; n0 is the number surface density of MPs at anode potential biasing on the substrate at a chosen time of metal plasma deposition; S is chosen for the statistically reliable counting of the MP quantity on substrate surface. For each experimental point total area for MP counting made 6 × 104 μm2.

Results and Discussion

A photograph of a typical substrate surface using electron microscope Hitachi TM-1000 after MPs and plasma deposition is presented in Fig. 2.

icontrolpollution-Microphotograph-titanium-plasma

Fig. 2: Microphotograph of a sample with different forms of MPs (titanium plasma, φb=0 V, deposition time is 3 min).

Fig. 2 shows that a lot of the small size MPs on the sample look like a sphere. At the same time, the MPs with diameter 3 μm and more is partly flattened.

The experiments with pulse repetition rates influence to MP number decreasing were carried out at the amplitude of the negative bias potential of 2 kV and pulse duration of 7 μs. Pulse frequency of the bias potential has been varied from 10 Hz to 105 Hz. Stainless steel or titanium samples of 2 cm3 × 2 cm3 × 0.3 cm3 in size were installed at 23 cm from cathode surface of vacuum arc plasma source. In all experiments, the processing time was 30 s. The experimental data of the MP amount on the sample versus pulse frequency are presented in Fig. 3. Increasing the bias pulse frequency from 10 Hz to 104 Hz led to a gradual reduction in the MP number acquisition on the target. However, this decrease did not exceed 20%. The character of the curve varies considerably in the bias-pulse frequency range of 104 Hz to 105 Hz. In this frequency range of the bias pulses, the surface MP number density decreased 5-fold.

icontrolpollution-repetition-processing-substrate

Fig. 3: MP number density (n) versus pulse repetition rate (f) at φb=–2 kV, a processing time of 30 s, and a cathode– steel substrate distance of 23 cm (ji=10 mA/cm2).

The experimental data concerning the decrease in the Ti MP acquisition versus the bias pulse duration at φb=–2 kV after 90 s of sample treatment has been carried out at cathode-substrate distance 38 cm (Ti ion plasma saturation current density ji=4.4 mA/cm2, and Ar plasma saturation current density ji=1.4 mA/ cm2) are presented in Fig. 4. Fig. 4 indicates that the MP accumulation on a substrate strongly depends on the bias pulse width.

icontrolpollution-Reduction-acquisition-cathode

Fig. 4: Reduction in the MP number acquisition on the target versus bias pulse length (τ) for φb=–2 kV, a processing time of 1.5 min and a cathode–titanium substrate distance of 38 cm.

Let’s consider the differences between DC and repetitively pulsed negative substrate biasing. Two processes occur when negatively charged plasma MPs enter the sheath. On the one hand, the velocity of the MPs decreases because of the interaction of negatively charged MPs with the sheath electric field. On the other hand, after entering the sheath, the MPs will be gradually recharged, both by the ions that interact with them and because of the ion– electron emission and thermionic emission from the surfaces of the MPs. In the sheath ions extracted from plasma boundary have rather high directed energy and, consequently, a directed velocity (~1.5 × 106 cm/s) that is two orders of magnitude higher than the velocity of the fastest MPs. Therefore, the positive charge stored on the MPs will depend on the sheath ion current density and the MPs cross section. If only the recharging of the MPs caused by the ion flux is taken into consideration, then as a first approximation, the time required for negative charge compensation on the MPs in the sheath can be estimated as follows:

equation   (1)

where z is the average charge state of the ions, e is the electron charge, n is the plasma density, υp is the plasma jet velocity, Q ≈ 4πεoMP is the negative charge accumulated by an MP in the plasma, R is the radius of an MP, φMP is the MP potential, and εo is the dielectric permeability.

According to Eq. 1, the recharge time for MPs in the sheath is approximately 10 μs at a plasma density of ~1010 cm-3. If an MP has not yet left the sheath before its negative charge is entirely lost, then it begins to gain a positive charge in the sheath and accelerates toward the dc-biased substrate surface. A thickness of the sheath s can be estimated from Child low of space-charge-limited current in a plane diode:

equation   (2)

where mi is the ion mass, U is the bias amplitude.

If an MP has an initial velocity of ~4 m/s, then it will penetrate a sheath with a thickness of ~4 mm within approximately 10-3 s. According to Eq. 1, during this time, the MPs can accumulate a positive charge with an absolute value that is two orders of magnitude greater than the negative charge accumulated in the plasma (during the same time). Thus, the MPs can be significantly accelerated as it approaches the substrate surface.

A different situation can arise in the case of the repetitively pulsed biasing. In this case, the MP, while approaching the substrate surface, will alternate between being located in the sheath (during the bias pulses) and in the plasma (in the intervals between pulses). In the sheath, the MP loses its negative charge as estimated by Eq. 1 for approximately 10 μs, which is comparable to the bias pulse duration in our experiments (7 μs). After the bias pulse cut off, the MP will again be located in the plasma, where it can get an additional negative charge. The droplet charging time in plasma is defined by the precise equality of the electron and ion currents to MP. For micron-sized droplets in a titanium arc plasma with a density of 1010 cm-3 this time will be several microseconds. It is evident that the MP recharging time in the plasma is comparable to the minimum interval between pulses (3 μs) at f=105 Hz in our experiments. Therefore, at a bias pulse repetition rate of 105 Hz, an MP with the initial velocity of 4 m/s penetrating a sheath with the thickness 4 mm will be subjected to approximately 100 recharging cycles in the sheath and in the plasma. Thus, upon the application of the repetitively pulsed biasing, repeated exposure of the sheath electric field to a negatively charged MP is possible.

The influence of the processing time on the decreasing of the surface MP number density was investigated at a negative bias potential amplitude of φb=–2 kV and a pulse length of 8 μs when metal vacuum arc and gaseous plasmas were used simultaneously.

The microphotographs in Fig. 5 show the change in MP density on substrate surface at the processing times 3 min, 9 min and 12 min at the high-frequency short-pulsed bias potential with the pulse amplitude φb=–2 kV, pulse width τ=8 μs and frequency f=105 Hz.

icontrolpollution-Microphotographs-titanium-coating

Fig. 5: Microphotographs of the titanium coating on titanium substrate after different time of ion-plasma treatment at bias pulse parameters f=105 Hz, φb=–2 kV and τ=8 μs: a) t=3 min; b) t=9 min; c) t=12 min.

The microphotographs in Fig. 2 and 5a show significant decrease in MPs number after the treatment time of 3 min at a pulsed bias potential in comparison with the MPs number were deposited at φb=0 V. The increase in treatment time to 12 min leads to a significant change in the sample surface morphology (Fig. 5c). The main reason of these surface changes can be associated with the increase of sample temperature depending on the treatment time and ion sputtering.

Fig. 6 demonstrates the various trends in MP behavior for MP diameters smaller and larger than 1.5 μm. For MPs of more than 1.5 μm in diameter, some stabilization (Fig. 6, curve 1) occurs such that for sufficiently long processing times, the large size MP amount is independent of the sample treatment time. Ultimately, a tenfold decrease in the MP surface density is reached for large MPs of more than 1.5 μm in diameter. For MPs of less than 1.5 μm in diameter, there is a rapid reduction in the relative surface MP number density with increasing processing time (Fig. 6, curve 2).

icontrolpollution-Reduction-treatment-droplets

Fig. 6: Reduction in the MP number acquisition on the target versus treatment time (t): 1) droplets diameter D>1.5 μm; 2) droplets diameter D<1.5 μm; 3) all MPs.

For a processing time of 18 min, the surface number density for MPs of less than 1.5 μm in diameter decreased 1500-fold. In fact, only individual MPs were observed on the surface after long time processing. Curve 3 in Fig. 6 indicates that for processing times of more than ~10 min a 67-fold reduction of droplets total number density has been achieved.

Conclusion

The possibility of control of MP number density on substrate immersed in vacuum arc and gas discharge plasma has been experimentally demonstrated.

It was found that the increase of the bias pulse repetition rate from 10 Hz to 105 Hz allow to change the titanium MP number surface density up to 5 times.

Changing of a bias pulse duration effects on MP number surface density.

The increasing of processing time of ion plasma substrate treatment to 8 min to 18 min allows to decrease the total titanium MP number surface density by 67 times.

Acknowledgments

The work was supported by Ministry of Education and Science of the Russian Federation.

References

  1. Aksenov, I.I., Belous, V.A., Padalka, V.G., and Khoroshikh, V.M. 1978. Apparatus to rid the plasma of vacuum arc of mocroparticles. Instrum. Exp. Tech. 21 : 1416-1418.
  2. Anders, A. 1999. Approaches to rid cathodic arc plasmas of macro- and nanoparticles: a review. Surf. Coat. Technol. 120-121 : 319-330.
  3. Bizyukov, A.A., Sereda, K.N., Kashaba, A.Y., Romaschenko, E.V., Chibisov, A.D., Ponevchinskiy, V.V., and Sleptsov, V.V. 2006. Evaporation of macroparticles in plasma of high-current pulsed arc discharge at low pressure. Prob. At. Sci. Technol. 5 : 136.
  4. Boxman, R.L., Sanders, D.M., and Martin, P.J. 1995. Handbook of Vacuum Arc Science and Technology: Fundamentals and Applications. Park Ridge NJ. Noyes.
  5. Daalder, J.E. 1976. Components of cathode erosion in vacuum arcs. J. Phys. D: Appl. Phys. 9 : 2379-2396.
  6. Keidar, M., Aharonov, R., and Beilis, I. 1999. Influence of an electrical field on the macroparticle size distribution in a vacuum arc. J. Vacuum. Sci. Technol. 17 : 3067-3073.
  7. Kondrat’eva, N.P., Koval’, N.N., Korolev, Y.D., and Schanin, P.M. 1999. A spectroscopic investigation of the near-cathode regions in a low-pressure arc. J. Phys. D: Appl. Phys. 32 : 699-704.
  8. Lunev, V.M., Padalka, V.G., and Khoroshikh, V.M. 1976. Plasma properties of a metal vacuum arc. Instrum. Exp. Tech. 19 : 1465-1495.
  9. Nikolaev, A.G., Oks, E.M., Savkin, K.P., Yushkov, G.Y., and Brown, I.G. 2012. Upgraded vacuum arc ion source for metal ion implantation. Rev. Sci. Instrum. 83 : 02A501.
  10. Plyutto, A.A., Ryzhkov, V.N., and Kapin, A.T. 1965. High Speed Plasma Streams in Vacuum Arcs. J. Exp. Theor. Phys. 20 : 328-337.
  11. Proskurovsky, D.I., Popov, S.A., Kozyrev, A.V., Pryadko, E.L., Batrakov, A.V., and Shishkov, A.N. 2007. Droplets evaporation in vacuum arc plasma. IEEE Trans. Plasma. Sci. 35 : 980-985.
  12. Randhawa, H. 1988. Cathodic arc plasma deposition technology. Thin Solid Films. 167 : 175-186.
  13. Ryabchikov, A.I., Sivin, D.O., and Bumagina, A.I. 2014. Physical mechanisms of macroparticles number density decreasing on a substrate immersed in vacuum arc plasma at negative high-frequency short-pulsed biasing. Appl. Surf. Sci. 305 : 487-491.
  14. Ryabchikov, A.I., Ryabchikov, I.A., Stepanov, I.B., and Sivin, D.O. 2005. Complementarity of X-ray diffraction and RBS in thin film characterization. Vacuum. 78 : 445-449.
  15. Rysanek, F., Rodney, L., and Burton, R.L. 2008. Charging of Macroparticles in a Pulsed Vacuum Arc Discharge. IEEE Trans. Plasma. Sci. 36 : 2147-2162.
  16. Sanders, D.M. 1989. Review of ion‐based coating processes derived from the cathodic arc. J. Vacuum. Sci. Technol. 7 : 2339-2345.
  17. Sharkeev, Y.P., Girsova, N.V., Ryabchikov, A.I., Kozlov, E.V., Perevalova, O.B., Brown, I.G., and Yao, X.Y. 1995. Dislocation structure in coarse-grained copper after ion implantation. Nucl. Inst. Methods. Phys. Res. 106 : 532-537.
  18. Stepanov, I.B., Ryabchikov, A.I., Ananin, P.S., Shevelev, A.E., Sivin, D.O., and Zhelomsky, S.G. 2016. Tangential cathode magnetic field and substrate bias influence on copper vacuum arc macroparticle content decreasing. Surf. Coat. Technol.
  19. Swift, P. 1996. Macroparticles in films deposited by steered cathodic arc. J. Phys. D: Appl. Phys. 29 : 2025-2031.
  20. Tau, C.N., Ko, E.S., and Akari, K. 1990. Macroparticles on TiN films prepared by the arc ion plating process. Surf. Coat. Technol. 43-44 : 324-346.
  21. Zhanga, G.P., Gaob, G.J., Wanga, X.Q., Lva, G.H., Zhoua, L., Chena, H., and Panga, H.Z. 2012. Influence of pulsed substrate bias on the structure and properties of Ti–Al–N films deposited by cathodic vacuum arc. Appl. Surf. Sci. 258 : 7274-7279.

Copyright © 2024 Research and Reviews, All Rights Reserved